Product Validation

The robustness of a product can only be validated with a good test facility.

We have invested into a self-sufficient in-house lab facility for carrying out Design Validation plans in compliance to latest ISO, JASO and SAE standards for electrical, environmental and mechanical tests for both 12V and 24V systems. We also support OEM specific test standards for carrying out DVP testing as per their requirements.

Our test facility is regularly audited by our OEM customers and is well maintained in timely manner in close liaison with equipment manufacturer. We keep upgrading and investing into our Test lab facility based on emerging needs from time to time. A dedicated team of expert test engineers who specialize in planning, conducting and analysing the test results works closely with engineering team for further design improvements based on test results.

Electrical Testing

Tests(12 v and 24 V systems)

  • Conducted Transients
  • Voltage Transient Emission Test
  • Abnormal signal conditions
  • Short Circuit
  • Open Circuit
  • Over voltage
  • Reverse polarity
  • Supply Voltage offset
  • Di-electric
  • Insulation Resistance
  • Electrostatic Discharge
  • Bulk Current Injection
  • Capacitive coupling clamp method
  • Conducted Emission (CE)
 
 

Environmental testing

  • High temperature storage
  • Low temperature storage
  • High temperature operation
  • Low temperature operation
  • Temperature cycle
  • Constant humidity
  • Temperature humidity cycle
  • Dew formation
  • Thermal shock
  • Water spray
  • Dust
  • Highly accelerated stress test (hast)
 

Mechanical Testing

  • Vibration under ambient condition 
  • Vibration under environmental conditions
  • Drop test
 
 

Endurance Testing

  • Endurance Testing as per customer requirement